Help

Intro to Directional Control Valves

Objectives

In this lesson we will discuss the purpose of a directional control valve, review the construction of a common directional control valve, and formulate and follow a logical and efficient troubleshooting plan to deal with a directional control valve problem.


The Problem

Congratulations! You are the proud owner of a small custom cabinet shop.

You've just finished unboxing and setting up a new and shiny press! The purpose of the press is to hold veneer evenly against a plywood sheet until the glue bonding the workpieces cures.

But…

The new press is only great until you try to use it in production. The cylinder behind the press extends and retracts correctly, but when you release the valve handle, the cylinder does not maintain the pressure against the workpieces, and the veneer starts to separate from the plywood.

It's a brand new system! What could the cause of the problem be? And how will you find it and fix it as efficiently as possible?

Cylinder
Pump
Tank
Pressure Gauge
Relief Valve
Check Valve
(hidden)
Directional
Control
Valve

The Circuit

Let's get started by quickly reviewing the major components in the press circuit.

This press uses a simple gear pump to push fluid to a tandem-center directional control valve, or DCV. When the valve is in neutral position, pump flow returns to tank. When you operate the lever, you extend or retract the press cylinder. A relief valve and pressure gauge are tied into the line from the pump.

Directional Control Valve Construction

Directional Control Valves (DCVs) are usually described by their ports, positions, centers, and operators. For example, if you were to describe the DCV in the press circuit, you would say that it is a 4 port, 3 position, tandem center, handle operated, spring centered valve.

Here's the same valve, shown as a schematic symbol.

P
T
A
B

It's a lot to say, but it's the only way to accurately describe a valve. Even if you happen to have its part number handy, it's best to know the complete description because manufacturers can (and do!) change part numbers without warning.

Ports

Pump
A Line
B Line
Tank

An example of a four-port valve. The four ports will always include the pump ("P") and tank ("T"). By convention, the other two lines will be labeled "A" and "B".

Ports refer to the number of lines into and out of the valve. The press circuit DCV has four ports to connect the valve to the pump, both sides of the cylinder, and to the tank. While four ports are very common, it's also easy to find examples of valves with 2 ports, 3 ports, and 6 ports. It's less common, but certainly not impossible, to find 5 and 7 port valves. There is no real limit, aside from practicality, on how many ports a valve could have.

Also Known As

Some people may refer to ports as "ways". For example, you may hear someone say that they have a 4 way, 3 position valve. This term is older, but still correct.

Positions

Most directional control valves are of a spool-type construction. The spool has lands and undercuts, housed within precision-machined casing. As the spool shifts, the lands and undercuts open and close flow paths.

Lands
Undercuts
Straight ThroughTandem CenterCrossover

The example valve has 3 positions: center, straight through (P to A), and crossover (P to B). The schematic clearly represents each position.

The graphic cutaway shows how the lands and undercuts on the spool form each position.

T
B
P
A
T
B
P
A
T
B
P
A

It's also common to see DCVs with two positions, or even four positions. Like ports, more positions are possible, but relatively uncommon.

Valves can also have infinite positions, which means that the valve spool does more than simply stop at one of the defined positions. It can also be sent to any point between one of the full positions in order to achieve flow control.

4 Position Valve

2 Position Valve

Infinite Position Valve

Centers

There are four common valve centers for four-port valves:

Open

Closed

Tandem

Float

T
B
P
A

An open center valve connects all four ports when the valve is centered.

T
B
P
A

A closed center valve blocks all four ports.

T
B
P
A

A tandem center blocks two ports, and connects two ports. Usually, it is used to block the A and B ports, and connect the pump to tank. This center is very common in applications like the simple press circuit, to allow the pump's flow to go straight to the tank, rather than forcing it over the relief valve.

T
B
P
A

A float center blocks a single port and connects the other three. It is usually used to block the pump, and connect A and B to tank.

Operators

Operator is a category that describes the mechanism that drives the valve to change its position. There are a lot of operators out there; the valve in the press circuit uses a handle (or lever), but you might also see a solenoid, or hydraulic pilot, to name a few.

Hydraulic Pilot

Solenoid

Handle

Responses are similar to operators, but they are never directly powered. Instead, they provide an automatic "response" that describes the valve's behaviour when its operator is not active. The valve from the example has a spring response. This means that when you are not using the lever to push it into the straight through or crossover position, the spring will return the spool to the center, tandem position.

Detent

Spring

Back to the Press

Now that we know a little more about DCVs, let's figure out how to troubleshoot that press.

Step One
Define the Problem

The first question to ask yourself is whether this is mostly* a flow, pressure, or directional problem.

*We use the word mostly because there can be a lot of overlap between categories. It's common to see flow problems cause pressure problems, and vice versa. The goal of this step is to consider the nature of the problem, and the characteristics of your system. Don't get caught here; spend a few minutes and then move on!

Flow Problem

Actuators move too fast, or too slowly.

Pressure Problem

When tackling the heaviest loads, actuators:

  • stall (in a kinetic state)
  • can't maintain position (in a static state)

Directional Problem

System normal in one direction only. Reverse function is compromised or non-existent.

Speed has not been a concern, and the cylinder extends and retracts properly. This is probably best categorized as a pressure problem.

Step Two
Consult the Schematic

If you have a schematic that is up to date, and verified for accuracy, congratulations! You are miles ahead in troubleshooting this problem. An accurate and trustworthy schematic is the key to a hydraulic system; it can provide:

  • a list of all of the components in the system, often including exact part numbers, codes and system-specific settings.
  • a diagram of the relationships between system components.
  • the exact location of test-points.
  • ways to isolate sub-circuits for testing purposes.

The manufacturer has provided a schematic with the manual, so you are ready to go.

Step Three
List Suspect Components

Make a list of all of the places where a failure could be causing the cylinder to release its hold on the workpieces. In Step 1 you determined that this is a pressure problem, so that will help to inform your choices here. You don't need to have a theory about what the exact failure is, just ask yourself whether any issue with a specific component could cause a pressure problem.

SUSPECT COMPONENTS
Directional Control
Valve
Hoses, Fittings
& Adaptors
Cylinder

Directional Control Valve

A failure within the valve could allow flow from the blind end of the cylinder to return to tank. It should certainly be on the list.

Hoses, Fittings, and Adaptors

It's unlikely that a system this small could pop a hose off without your notice, have a hose that is over crimped, or a fitting that was drilled improperly, but it's easy to check and worth eliminating. Put it on the list.

Cylinder

Since the major symptom seems to be that we are unable to hold pressure in the blind end of the cylinder, it belongs on the list to be checked out.

Pump

Since the pump generates flow, not pressure, it's unlikely to be the cause of a pressure problem. Flow seems to be adequate; we can leave the pump off of the list.

Relief Valve

The job of the relief valve is to limit system pressure and protect the system from sudden pressure shocks. The system is under the most pressure when the cylinder is moving to compress the workpieces, but it is able to build up to the correct pressure. The relief valve is unlikely to be the culprit. Leave it off the list.

Reservoir

The problems that could originate from the reservoir - fluid level too high, too low, or a plugged filter or breather, would not explain the symptoms we are seeing. We can leave the reservoir off of the list.

Check Valve

A check valve can stick, either in an open, closed, or partially-open position. However, none of those scenarios would cause the symptoms that you're seeing. Leave it off of the list.

Step Four
Isolate Sub-Circuits

This step does not always apply. Some simple hydraulic circuits do not have subcircuits that can be easily isolated. This circuit is extremely small and simple - there really isn't a practical way to isolate any part of it.

You've probably noticed by now that we are using a rather rigorous approach to troubleshooting a problem in a very simple circuit. While it might be overkill in this example, practicing good troubleshooting habits when working with simple problems will keep you on track when working with larger and more complex systems.

Step Five
Determine Order of Checking

You've shaved the list of suspect components down, which is certainly progress. But which of the suspect components should be checked first?

Many people would start with the most likely culprit, but that might not be the most efficient troubleshooting strategy. Instead, start with the easiest item(s) to check externally, without removing them from the circuit.

Arrange your list by dragging the items into the easiest-to-check order.

SUSPECT COMPONENTS
1.
2.
3.
Directional Control
Valve
Cylinder
Hoses, Fittings
& Adaptors

Step Six
Physical Observations

You can often discover a faulty component, or eliminate it from your suspect list, without taking the system apart.

Fittings, Hoses, and Adaptors

Checking the hoses, fittings, and adaptors is really easy to do, so why not get it out of the way first and cross it off your list?

Examine the exposed hoses and fittings for wetness/leakage. While this step is very simple, it can be dangerous if you don't follow some basic safety precautions. Wear your PPE and do not touch fittings or hoses when system is under pressure. This means:

  • No flexing a suspicious hose to see what happens.
  • Don't run your hand over hoses or fittings to look for leaks, unless you have completely depressurized the system. Gloves won't protect you from an injection injury!
  • Don't wiggle fittings to see if you can make them leak.

Be cautious around all leaks (or suspected leaks) in a pressurized system.

You've safely checked the hoses and fittings, and found nothing suspicious. Time to continue down the list.

SUSPECT COMPONENTS
1. Hoses, Fittings & Adaptors
2. Directional Control Valve
3. Cylinder

DCV

The major symptom is that pressure is not held in the blind end of the cylinder once the valve recenters. If there is a flow path through the valve from A to T when the valve has centered, that would explain the pressure problem.

What tests can you make by just using your senses and observing the system?
A Line is rigid when the cylinder is extending.
A Line sags as soon as the valve is in neutral position.

You observe that the flexible hose leading to the blind end of the cylinder stiffens when extending the cylinder, but relaxes and sags immediately when the valve centers. This would suggest that the hose is suddenly at atmospheric pressure.

How would that hose suddenly become depressurized?

Cylinder

If flow is able to creep over the piston seal from the blind end to the rod end, there might be enough clearance in the valve spool to allow that flow to escape back to tank.

You visually inspect the cylinder for signs of a leak. You listen carefully as the cylinder is extending against pressure, but cannot detect any suspicious hissing that would indicate flow passing around the piston seal.

Suspect Components
1. Hoses & Fittings
2. Directional Control Valve ??
3. Cylinder

Conclusions

If a leak in the cylinder is the problem, it's unlikely that the line from the valve to the blind end of the cylinder would suddenly and completely depressurize in the way you have observed. A slow, creeping change would make more sense if a leak was the problem.

It seems more likely that the pressurized fluid in the blind end of the cylinder is finding an easy path back to tank the moment the valve has centered. It's time to move on to the next step: it's time to test and hopefully confirm this theory.

Step Seven
Test Components

Confirm your observation that pressure on the A line is, indeed, dropping to zero (or near zero) almost immediately.

You remove the blind end line from the cylinder, and attach a gauge to get an objective measure of what's going on in that line. You find that the pressure drops from about 3000 psi to near zero in a split second as you allow the valve to recenter.

This should not be happening - the tandem center in the valve should hold the pressure when the valve centers. There is clearly a problem with the valve.

Step Eight
Repair/Replace

You've done enough due diligence at this point to be confident that the valve is the source of the problem. This particular DCV is not very expensive, so it's easy to replace, and not very practical to repair. Within a couple of hours you've swapped a new one into the system.

Step Nine
Verify!

It's the moment of truth! It's time to operate the press and verify that the problem has disappeared. Make sure to test the press under load, and at normal operating conditions before declaring that you're done.

Hurray! The press operates as advertised; extending, retracting, and holding pressure correctly. The DCV was the source of the pressure problem.

Ready for the last step?

Step Ten
Why Did it Happen?

Finding the Root Cause

Now that you are certain that the DCV was the source of the problem, it's time to devote a little more brainpower to the problem, and understand why. Since it's a brand new piece of equipment, it shouldn't have failed at all, and understanding the "why" will help you decide whether it is likely to fail again in short order. Should the whole system be boxed up and returned?

Tandem Center

A tandem center valve would trap fluid in the cylinder when the valve is in neutral.

Open Center

The open center valve provides an easy path back to tank when the valve is in neutral. No wonder the pressure falls as soon as the valve is in neutral!

The valve that shipped with the veneer press was actually an open center valve.

The easiest way to learn more about the valve is to take it apart. As soon as you do, you notice that the spool doesn't look quite right. The wrong valve was bundled with the system; you're looking at an open center, not a tandem center. So while there was nothing wrong with the valve itself, it was the wrong valve for the system. Now that you have installed the correct valve, there is no reason to expect any further problems.

Put your schematic away in a safe place, and get to work making cabinets!

Review

What is the primary purpose of a directional control valve?

Describe The Valve

Drag and drop the terms to correctly complete the description of this valve. Some terms will not be needed.

"This is a: port, (or way), position, operated, centered, center valve."

256pilotsolenoidtandem

If the valve on the veneer press had a CLOSED center, instead, what behavior would you expect to see when the valve is in neutral?

If the valve on the veneer press had a FLOAT center, what behavior would you expect to see when the valve is in neutral?

Recap

  • DCVs are used to direct flow through a hydraulic system.
  • DCVs are described in terms of their ports, positions (ways), centers, and operators.
  • There are four common center positions: Open, Closed, Tandem and Float
  • An open center allows fluid to drain back to tank.
  • A closed center blocks all lines.
  • A float center connects lines A and B to tank.
  • A tandem center connects the pump to the tank.

We hope you enjoyed Intro to Directional Control Valves

Loading
Vacuum Pressure
Drain Pressure
Low Pressure
Medium Pressure
High Pressure
Ground/Common
Lowest Voltage
Medium Voltage
Highest Voltage
Magnetic Field
Check Your Console