IntegratedPump / Valve / ReliefDriven Off Host PumpHoist System TankReliefValve3000 PSI(206.8) Bar24 VDC SolenoidThermostaticallyControlledPQ = 8 GPM (30.3 LPM) @ Engine = 1900 RPMQ = 3 GPM (11.4 LPM) @ Engine = 700 RPMRelief Valve300 PSI(20.7 Bar)Relief Valve300 PSI(20.7 Bar)Combinatuion Motor /Tandem Pump Located OnBackside Of HoiseCrosstubeRH Side GearboxLube Oil SumpRH WheelMotorLH Side GearboxLube Oil SumpLH WheelMotorAir Baffle BoxAxel Box13055-S FilterBypass = 25 PSI (1.7 Bar)Element = 13055-S-1V = 950 fpmOil Cooler Located In Front Of RadiatorCheck Valve CrackingPressure = 65 Psi (4.5 Bar)Q = 8 GPM (30.3 LPM) @ Engine = 1900 RPMQ = 3 GPM (11.4 LPM) @ Engine = 700 RPMTypical Both Circuits